Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22.975
Filtrar
1.
Zhongguo Gu Shang ; 37(4): 392-8, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38664211

RESUMO

OBJECTIVE: To evaluate the rabbit modle of frozen shoulder induced by persistent strain injuries and ice compression. METHODS: Twelve clean, healthy male New Zealand rabbits with a mass of (2 500±500) g were selected and randomly divided into a blank group and a control group with 6 rabbits in each group. In the control group, the rabbits were modeled with persistent strain injuries and ice compression, the general conditions of the rabbits and the active and passive activities of the shoulder joint were observed and their body weights were recorded. MRI was performed on the affected shoulder joints at 6 d and 29 d after modelling to observe the fluid and soft tissue;HE staining was used to observe the morphology of the rabbit biceps longus tendon and the synovial membrane of the joint capsule;Masson staining was used to observe the fibrous deposits of the rabbit biceps longus tendon and the synovial membrane of the joint capsule, and the fibrous deposits were analysed semi-quantitatively by Image J software. RESULTS: Six days after the end of modeling, the active movement of the shoulder joints in the control group was limited, the passive movement was not significantly limited, and they walked with a limp;29 days after the end of the modeling, the active and passive movements of the shoulder joints in the model group were severely limited. Compared with the blank group (2.50±0.14) kg, the body weight of the model group (2.20±0.17) kg was significantly reduced(P<0.01). MRI showed that 6 days after modelling, the muscles around the shoulder joint were not smooth in shape, the joint capsule structure was narrowed and a large amount of fluid was seen in the joint cavity;29 days after modelling, the muscles around the shoulder joint were rough in shape, structure of the joint capsule was unclear and the fluid in the joint cavity was reduced compared with 6 days after modelling. Pathological staining showed that the long-headed biceps tendon fibres in the control group were disorganised, curled or even broken, and the synovial tissue of the joint capsule was heavily vascularised, with collagen fibre deposits and severe inflammatory cell infiltration. The fiber deposition of the long head of biceps brachii in the model group [(23.58±3.41)%, (27.56±3.70)%] and synovial tissue [(41.78±5.59)%, (62.19±7.54)%] were significantly higher than those in the blank group [(1.79±1.03) %, (1.29±0.63) %] at 7 and 30 days after modeling and synovial tissue fiber deposition [(8.15±3.61) %, (11.29±7.10) %], as shown by the semi-quantitative analysis of Masson staining results by Image J software. And the longer the time, the more severe the fibrosis (P<0.01). CONCLUSION: The behavioral, imaging and pathological findings showed that the rabbit frozen shoulder model with persistent strain injuries and ice compression is consistent with the clinical manifestations and pathogenesis of periarthritis, making it an ideal method for periarthritis research.


Assuntos
Bursite , Modelos Animais de Doenças , Animais , Coelhos , Masculino , Bursite/fisiopatologia , Gelo , Entorses e Distensões/fisiopatologia , Articulação do Ombro/fisiopatologia , Imageamento por Ressonância Magnética
2.
BMC Musculoskelet Disord ; 25(1): 305, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643086

RESUMO

BACKGROUND: Historically, in-person physical therapy serves as a foundational component of nonoperative treatment of adhesive capsulitis (AC). This study compares the effectiveness of an at-home high-intensity stretch (HIS) device to traditional physical therapy (PT) and to PT in combination with the HIS device. We hypothesize that the HIS device will be as effective as PT alone or as combination therapy in the first-line treatment of AC and use of the HIS device will exhibit improvement at higher rate. METHODS: Thirty-four patients with idiopathic adhesive capsulitis and a minimum of 12 months follow-up were included in this study. Patients were randomized into one of the three groups: HIS device, PT alone, or HIS device + PT. Passive range of motion (ROM), American Shoulder and Elbow Surgeons (ASES), and Simple Shoulder Test (SST) scores were measured. Additionally, patient satisfaction, compliance and complications were recorded. Paired t-test, ANOVA and Chi-squared tests were used in analysis. RESULTS: Final ROM in all planes improved for all groups compared to baseline (p < 0.001), with only HIS device group able to restore > 95% of contralateral ROM in all planes at final follow-up. Patients with PT alone were on average slowest to improve ROM from baseline, at 3 months, 6 months, and 1 year in all planes except internal rotation. ASES and SST scores improved for all groups when compared to baseline (p < 0.001). Use of HIS-device resulted in greater improvement in SST and ASES Total scores compared to PT alone (p = 0.045, and p = 0.048, respectively). CONCLUSIONS: Use of an at-home high-intensity stretching device for conservative treatment of idiopathic adhesive capsulitis improves outcomes in ROM and in ASES and SST scores both when used as an adjunct to physical therapy and when used alone. TRIAL REGISTRATION: The study protocol was registered at www. CLINICALTRIALS: gov (20/05/2022, NCT05384093).


Assuntos
Bursite , Articulação do Ombro , Humanos , Resultado do Tratamento , Estudos Prospectivos , Bursite/terapia , Bursite/complicações , Modalidades de Fisioterapia , Amplitude de Movimento Articular
3.
J Orthop Traumatol ; 25(1): 20, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637350

RESUMO

BACKGROUND: This study aims to compare the range of motion (ROM) of reverse shoulder arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) component to regular reverse shoulder arthroplasty (RSA) lateralised by using a 42-mm glenoid component. The secondary aims are to compare patient-reported and radiographic outcomes between the two groups. MATERIALS AND METHODS: All patients with a BIO-RSA and size 38 glenosphere were retrospectively identified and matched to patients with a regular RSA and size 42 glenosphere. Matched patients were invited for a follow-up visit. ROM was assessed as well as radiographic outcomes (lateralisation, distalisation, inferior overhang, scapular notching, heterotopic bone formation, radiolucency, stress shielding, bone graft healing and viability and complications) and patient-reported outcomes (subjective shoulder value, Constant score, American Shoulder and Elbow Surgeons, activities of daily living which require internal rotation, activities of daily living which require external rotation and a visual analogue scale for pain). Outcomes were compared between the two groups. RESULTS: In total, 38 BIO-RSAs with a size 38 glenosphere were matched to 38 regular RSAs with a size 42 glenosphere. Of the 76 matched patients, 74 could be contacted and 70 (95%) were included. At the final follow-up, there were no differences between the two groups in ROM, patient-reported outcomes or radiographic outcomes (p > 0.485). CONCLUSIONS: Using a larger glenosphere is a feasible alternative to BIO-RSA for lateralising RSA, providing comparable ROM, patient-reported and radiographic results, while potentially decreasing costs, operative time and complication rates.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Atividades Cotidianas , Escápula/diagnóstico por imagem , Escápula/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
4.
Med Sci Monit ; 30: e943703, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38637980

RESUMO

BACKGROUND This retrospective study investigated the association between the critical shoulder angle (CSA) and the development of full-thickness rotator cuff tears (FTRCTs) in the Turkish population. The CSA is an imaging parameter that quantifies the relationship between the inclination of the glenoid and the lateral extension of the acromion in the coronal plane. The CSA is an anatomical measurement, and higher CSA values have been associated with an increased incidence of FTRCTs. However, there is a lack of data on CSA regarding the Turkish population. MATERIAL AND METHODS In this study, CSA measurements were recorded in 2 groups: 50 patients with FTRCT who had arthroscopic repair (group 1) and 50 age- and sex-matched individuals with no FTRCT detected by magnetic resonance imaging (group 2). Sex, age, affected side, dominant side, and smoking status were recorded for each patient. The CSA measurements of the affected sides were performed on true anterior-posterior view radiographs. RESULTS The results showed a statistically significant difference between the mean CSA values of group 1 (37.48°) and group 2 (33.53°), P<0.001. CSA values of 36 and above had a sensitivity of 73.58%, specificity of 74.47%, positive predictive value of 75%, and negative predictive value of 74.47% for detecting FTRCT. CONCLUSIONS CSA measurement on radiographs is a useful diagnostic tool in the Turkish population, and an above-average CSA value is associated with a significantly increased incidence of degenerative-type FTRCT.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Ombro/diagnóstico por imagem , Lesões do Manguito Rotador/diagnóstico por imagem , Estudos de Coortes , Estudos Retrospectivos
5.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562639

RESUMO

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Escápula , Amplitude de Movimento Articular , Fenômenos Biomecânicos
6.
Clin Orthop Surg ; 16(2): 294-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562643

RESUMO

Background: There are few reports on the revision or reintervention of reverse total shoulder arthroplasty (RTSA) in South Korea. The purpose of this study was to evaluate the true incidence of complications and reintervention of RTSA and clinical and radiological outcomes based on our 14-year experience in RTSA in a Korean population. Methods: Between March 2008 and June 2022, 412 consecutive cases of RTSA were performed in 388 patients with an average age of 74.4 years at our institute. Excluding 23 patients lost to follow-up, 365 patients (373 shoulders including 8 bilateral cases) who underwent primary RTSA with more than 6 months of follow-up were enrolled in this study. We evaluated those who had complications or reintervention including revision RTSA for failed RTSA. Patient charts were reviewed, and clinical outcomes including clinical scores, complications, and reintervention and radiologic outcomes were evaluated at the last follow-up. Results: Among the 373 shoulders that underwent primary RTSA, complications were found in 50 patients (13.94%, 10 men and 40 women with a mean age of 75.9 ± 6.7 years [range, 51-87 years]). The causes of complications were as follows: 13 acromion, coracoid, or scapular spine fractures, 10 loosening (glenoid: 5, humeral stem: 5), 5 infections, 4 periprosthetic fractures, 2 instability, 2 neurologic complications, and 14 miscellaneous complications. Twenty patients (5.63%, 4 men and 16 women with a mean age of 74.2 ± 8.2 years [range, 51-87 years]) underwent reintervention. The interval to the first reintervention was 27.8 ± 23.1 months (range, 0.1-78 months). The causes of reintervention (20 cases) were 8 loosening (glenoid: 4, humeral stem: 4), 5 infections, 5 fractures, and 2 instability. Among them, 15 component revisions (4.02%) were performed. At the last follow-up, American Shoulder and Elbow Surgeons, University of California at Los Angeles, and Simple Shoulder Test scores were improved from 25.4, 12.4, and 1.6 preoperatively to 40.4, 16.2, and 3.2, respectively. Forward flexion (48° to 87°), abduction (52° to 79°), external rotation (18° to 22°), and internal rotation (buttock to L2) were improved. Conclusions: After primary RTSA in a Korean population, the complication, reintervention, and revision rates were 13.94%, 5.63%, and 4.02%, respectively. Careful evaluation of the complications and adequate treatments should be performed.


Assuntos
Artroplastia do Ombro , Fraturas Periprotéticas , Articulação do Ombro , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento , Fraturas Periprotéticas/etiologia , Escápula , Estudos Retrospectivos , Amplitude de Movimento Articular , Reoperação/efeitos adversos
7.
JBJS Rev ; 12(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38574183

RESUMO

¼ Reverse total shoulder arthroplasty was designed to function in the rotator cuff deficient shoulder by adjusting the glenohumeral center of rotation (COR) to maximize deltoid function.¼ Adjustments in the COR ultimately lead to changes in resting tension of the deltoid and remaining rotator cuff, which can affect implant stability and risk of stress fracture.¼ Soft-tissue balance and complication profiles can be affected by humeral component (version, neck shaft angle, and inlay vs. onlay) and glenoid component (sagittal placement, version, inclination, and lateralization) design and application.¼ A good understanding of the effects on soft-tissue balance and complication profile is critical for surgeons to best provide optimal patient outcomes.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Manguito Rotador/cirurgia
8.
J Orthop Surg Res ; 19(1): 222, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576016

RESUMO

BACKGROUND: To compare the histopathological results of biceps tenodesis (BT) performed with normal, low, and high pressures for superior capsule reconstruction (SCR) in rabbits with massive rotator cuff tears. MATERIALS AND METHODS: Thirty rabbits were divided into three groups. Rabbits 1-10 underwent SCR with BT at the same pressure (Group 1), value measured in the groove; 50% lower (Group 2); 50% higher (Group 3). After the 4-week follow-up, shoulder were en-bloc excised and histopathological evaluation was performed with modified Bonar's scale. Results were compared between the groups, statistically. RESULTS: Extracellular matrix were significantly lower in group 2 compared to the other groups (p < 0.05). Cellularity levels were significantly lower in group 2 compared to the other groups (p < 0.05). Group 2 had no difference between the sides (p > 0.05). Group 2 had lower vascularity levels compared to the other groups (p = 0.01). DICSUSSION: When the biceps tendon was in the bicipital groove and in a more mobile state with lower pressure exposure. BT performed with a tension that creates less pressure than the biceps in the groove is more successful in SCR.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Tenodese , Coelhos , Animais , Tenodese/métodos , Músculo Esquelético/cirurgia , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Tendões/cirurgia , Tendões/patologia , Braço/cirurgia , Articulação do Ombro/cirurgia , Artroscopia/métodos
9.
PLoS One ; 19(4): e0301320, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630752

RESUMO

Movement systems are massively redundant, and there are always multiple movement solutions to any task demand; motor abundance. Movement consequently exhibits 'repetition without repetition', where movement outcomes are preserved but the kinematic details of the movement vary across repetitions. The uncontrolled manifold (UCM) concept is one of several methods that analyses movement variability with respect to task goals, to quantify repetition without repetition and test hypotheses about the control architecture producing a given abundant response to a task demand. However, like all these methods, UCM is under-constrained in how it decomposes a task and performance. In this paper, we propose and test a theoretical framework for constraining UCM analysis, specifically the perception of task-dynamical affordances. Participants threw tennis balls to hit a target set at 5m, 10m or 15m, and we performed UCM analysis on the shoulder-elbow-wrist joint angles with respect to variables derived from an affordance analysis of this task as well as more typical biomechanical variables. The affordance-based UCM analysis performed well, although data also showed thrower dynamics (effectivities) need to be accounted for as well. We discuss how the theoretical framework of affordances and affordance-based control can be connected to motor abundance methods in the future.


Assuntos
Movimento , Articulação do Ombro , Humanos , Movimento/fisiologia , Articulação do Ombro/fisiologia , Fenômenos Biomecânicos
10.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 505-510, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632074

RESUMO

Objective: To review the research progress of ultrasound in the diagnosis and treatment of shoulder diseases, in order to provide a theoretical basis for the further development of ultrasound in shoulder surgery. Methods: The recent literature on the application of ultrasound in the shoulder joint was extensively reviewed. The application of ultrasound in the diagnosis and treatment of shoulder joint diseases, and the advantages and disadvantages of ultrasound were analysed, and the development trend of ultrasound technology in the shoulder joint area was prospected. Results: At present, the diagnosis of shoulder joint diseases mainly relies on MRI, however, with the development of ultrasound technology, ultrasound with the characteristics of convenient, reliable, and real-time dynamic evaluation is more and more recognized in the diagnosis process of shoulder joint diseases, combined with three-dimensional ultrasound, ultrasound intervention, and elastography can improve the accuracy, sensitivity, and specificity of the diagnosis, and is suitable for the diagnosis and treatment of various shoulder joint diseases, which is expected to carry out early prevention of shoulder joint diseases in the future and achieve more refined and minimally invasive treatment. Conclusion: Ultrasound technology has wide application prospect in shoulder joint diseases, but it is still in the developing stage, and the subjective dependence needs to be solved further.


Assuntos
Artropatias , Articulação do Ombro , Humanos , Ultrassonografia , Imageamento por Ressonância Magnética , Ombro
11.
Praxis (Bern 1994) ; 113(3): 68-73, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38655732

RESUMO

INTRODUCTION: The Frozen Shoulder is a frequently encountered pathology in clinical practice. This condition often coexists with various comorbidities and is characterized by severe pain and a significantly restricted motion of the affected shoulder. A limited passive external rotation with the arm in adduction, with no signs of any other pathology that could explain the finding, such as shoulder osteoarthritis or an undetected posterior dislocation, is pathognomonic. The course of the disease typically spans over one to two years and is usually self-limiting. In the vast majority of cases, this condition can be managed conservatively. Keywords: shoulder, shoulder stiffness, shoulder pain, conservative therapy.


Assuntos
Bursite , Bursite/terapia , Bursite/diagnóstico , Humanos , Diagnóstico Diferencial , Dor de Ombro/terapia , Dor de Ombro/etiologia , Articulação do Ombro/fisiopatologia
12.
JBJS Rev ; 12(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38619382

RESUMO

¼ Posterior glenohumeral instability is relatively uncommon compared with anterior instability, but is becoming an increasingly recognized and surgically managed shoulder pathology.¼ Soft-tissue stabilization alone may not be sufficient in patients who present with substantial bone loss to the posterior glenoid and/or the anterior humeral head.¼ For posterior glenoid defects, posterior glenoid osteoarticular augmentation can be used, and posterior glenoid opening wedge osteotomy can be considered in cases of posterior instability with pathologic retroversion.¼ For humeral head lesions, several surgical treatment options are available including subscapularis transposition into the humeral head defect, autograft or allograft reconstruction, humeral rotation osteotomy, and shoulder arthroplasty.


Assuntos
Instabilidade Articular , Articulação do Ombro , Humanos , Ombro , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Escápula , Cabeça do Úmero/cirurgia
13.
PeerJ ; 12: e16960, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38436017

RESUMO

Important transformations of the pectoral girdle are related to the appearance of flight capabilities in the Dinosauria. Previous studies on this topic focused mainly on paravians yet recent data suggests flight evolved in dinosaurs several times, including at least once among non-avialan paravians. Thus, to fully explore the evolution of flight-related avian shoulder girdle characteristics, it is necessary to compare morphology more broadly. Here, we present information from pennaraptoran specimens preserving pectoral girdle elements, including all purportedly volant taxa, and extensively compare aspects of the shoulder joint. The results show that many pectoral girdle modifications appear during the evolution from basal pennaraptorans to paravians, including changes in the orientation of the coracoid body and the location of the articulation between the furcula and scapula. These modifications suggest a change in forelimb range of motion preceded the origin of flight in paravians. During the evolution of early avialans, additional flight adaptive transformations occur, such as the separation of the scapula and coracoid and reduction of the articular surface between these two bones, reduction in the angle between these two elements, and elongation of the coracoid. The diversity of coracoid morphologies and types of articulations joining the scapula-coracoid suggest that each early avialan lineage evolved these features in parallel as they independently evolved more refined flight capabilities. In early ornithothoracines, the orientation of the glenoid fossa and location of the acrocoracoid approaches the condition in extant birds, suggesting a greater range of motion in the flight stroke, which may represent the acquisition of improved powered flight capabilities, such as ground take-off. The formation of a new articulation between the coracoid and furcula in the Ornithuromorpha is the last step in the formation of an osseous triosseal canal, which may indicate the complete acquisition of the modern flight apparatus. These morphological transitions equipped birds with a greater range of motion, increased and more efficient muscular output and while at the same time transmitting the increased pressure being generated by ever more powerful flapping movements in such a way as to protect the organs. The driving factors and functional adaptations of many of these transitional morphologies are as yet unclear although ontogenetic transitions in forelimb function observed in extant birds provide an excellent framework through which we can explore the behavior of Mesozoic pennaraptorans.


Assuntos
Dinossauros , Articulação do Ombro , Animais , Extremidade Superior , Membro Anterior , Aves , Escápula
14.
Wiad Lek ; 77(1): 55-61, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38431808

RESUMO

OBJECTIVE: Aim: To compare the effectiveness of end-range mobilization and therapeutic exercises, used in combination with ischemic compression, on disability and pain indicators among patients with adhesive capsulitis of the shoulder joint and thoracic myofascial pain syndrome. PATIENTS AND METHODS: Materials and Methods: The study involved 68 patients. Goniometry of the shoulder joint, assessment of pain in myofascial trigger points, and the Shoulder Pain and Disability Index questionnaire were used before and after physical therapy. The duration of physical therapy comprised 3 weeks. Physical therapy of the first group of patients consisted of end-range mobilization and ischemic compression. Patients of the second group performed therapeutic exercises and ischemic compression. RESULTS: Results: Both groups demonstrated positive dynamics of shoulder joint mobility, Shoulder Pain and Disability Index and pain in trigger points. However, the final results of the studied indicators were better in the first group of patients. CONCLUSION: Conclusions: Physical therapy based on the combination of end-range mobilization and ischemic compression had a more positive impact on disability and pain indicators for adhesive capsulitis of the shoulder joint and myofascial pain syndrome as compared to the combination of therapeutic exercises and ischemic compression.


Assuntos
Bursite , Síndromes da Dor Miofascial , Articulação do Ombro , Humanos , Dor de Ombro/terapia , Resultado do Tratamento , Modalidades de Fisioterapia , Síndromes da Dor Miofascial/terapia , Bursite/terapia , Bursite/reabilitação
15.
J Bodyw Mov Ther ; 37: 121-130, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38432793

RESUMO

OBJECTIVE: To indicate the benefits and limitations of the isokinetic test results for the performance of the main shoulder joint movements in swimmers, considering the different competitive levels, swimming techniques, race distances, and sex. METHODS: Search on the PubMed, CENTRAL, Medline, LILACS, and SCOPUS databases for the oldest records up to October 2022. Risk of bias, methodological quality, and level of evidence were evaluated based on the NHLBI checklist. RESULTS: 29 articles met the criteria and were included in this study. The quality analysis classified three as "good" and 26 as "regular", with a KAPPA index of 0.87. The main benefits found involved assessments of the clinical condition of the shoulder joint complex, relationships with performance, and reliability studies. The limitations found point to the participant's positioning in the instrument, use of angular velocity above 180°/s, and sample size. CONCLUSION: The use of the isokinetic dynamometer allows verifying the levels of strength, endurance, balance, and asymmetries among swimmers of different techniques, distances, competitive levels, and sex. Thus, it helps in the analysis and monitoring of the clinical conditions of swimmers' shoulder joints, contributing to the decision-making process of physiotherapists and coaches.


Assuntos
Articulação do Ombro , Natação , Humanos , Reprodutibilidade dos Testes , Ombro/fisiologia , Articulação do Ombro/fisiologia , Natação/fisiologia
16.
J Bodyw Mov Ther ; 37: 57-62, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38432842

RESUMO

INTRODUCTION: Shoulder injuries in baseball players cause excessive shoulder load during pitching and scapular dyskinesis (SD). However, the characteristics of pitching kinetics in the shoulder joint with SD are unclear. This study aimed to investigate the effect of SD on pitching kinetics in the shoulder joint of baseball players. METHOD: Seventy-two college and independent league baseball players participated in the study. The pitching motion was measured using an 18-camera motion-capture system. SD was classified into four types (I-IV) using the scapular dyskinesis test (SDT). The pitching kinetics data were analyzed. RESULTS: The agreement of SD in this study was 56/72 (77.8%). SD were classified into 31 abnormal group (type I-Ⅲ) and 25 control group (type Ⅳ). Three participants with measurement failure during the pitching motion analysis were excluded from the analysis. The abnormal group showed a larger maximum value of the glenohumeral normalized anterior joint force than the control group. CONCLUSIONS: These results suggest that an increase in GH anterior force during pitching causes an excessive increase in external rotation of the GH with an insufficient posterior tilt of the scapula with SD. Therefore, baseball pitching with SD may involve shoulder injuries owing to excessive shoulder load during pitching.


Assuntos
Beisebol , Discinesias , Lesões do Ombro , Articulação do Ombro , Humanos , Ombro , Escápula , Discinesias/etiologia
17.
J Orthop Surg Res ; 19(1): 159, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429849

RESUMO

BACKGROUND: The shoulder joint is the most commonly dislocated joint in the human body, and the recurrence rate exceeds 50% after nonsurgical treatment. Although surgical treatment reduces the recurrence rate, there is controversy regarding the optimal surgical approach. Previous studies suggest that the Latarjet procedure yields favourable outcomes for specific populations at risk of recurrence, such as competitive athletes with significant glenoid defects. However, most of the existing related research consists of nonrandomized controlled trials with small sample sizes, and there is a lack of strong evidence regarding the efficacy and safety of the Latarjet procedure. METHODS: The PubMed, Embase, Cochrane Library, and Web of Science databases were systematically searched. Athletes with ≥ 20% glenoid defects were selected for inclusion. The following data were extracted: general patient information, instability rates, return to sports (RTS) rates, imaging features (graft positioning rate and graft healing rate), functional assessments [Rowe score, Athletic Shoulder Outcome Scoring System(ASOSS), visual analogue scale (VAS), forward flexion function, and external rotation function], and complications. RESULTS: After excluding suspected duplicate cases, a total of 5 studies were included in this meta-analysis. The studies involved a total of 255 patients, including 237 males (93%) and 18 females (7%). The average age at the time of surgery was 25.4 ± 8.5 years. All the studies had a minimum follow-up period of 2 years, with an average follow-up time of 48.7 ± 18.9 months. The pooled rate of return to sport (RTS) was 94.3% (95% CI: 87.3%, 98.8%), and 86.1% (95% CI: 78.2%, 92.5%) of patients returned to their preoperative level of activity. The pooled redislocation rate was 1.1% (95% CI: 0%, 3.8%). Regarding the imaging results, the combined graft retention rate was 92.1% (95% CI: 88.1%, 95.5%), and the graft healing rate was 92.1% (95% CI: 88%, 95.4%). Postoperative functional evaluation revealed that the combined Rowe score, ASOSS score, and VAS score were 93.7 ± 6.5 points, 88.5 ± 4.4 points, and 1.1 ± 10 points, respectively. The forward flexion and external rotation angles were 170.9 ± 6.9 degrees and 65.6 ± 4.5 degrees, respectively. After excluding one study with unclear complications, the combined complication rate was 9.4% (95% CI: 1.0%, 23.6%). CONCLUSION: For athletes with shoulder instability and a total of ≥ 20% glenoid bone defects, the Latarjet procedure can achieve excellent functional outcomes, with the majority of patients returning to preoperative levels of sports activity. This procedure also leads to a low recurrence rate. Therefore, the Latarjet procedure has been proven to be a safe and effective treatment.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Instabilidade Articular/cirurgia , Escápula/cirurgia , Atletas
18.
BMC Musculoskelet Disord ; 25(1): 204, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454432

RESUMO

BACKGROUND: The two major reverse shoulder arthroplasty (RSA) designs are the Grammont design and the lateralized design. Even if the lateralized design is biomechanically favored, the classic Grammont prosthesis continues to be used. Functional and subjective patient scores as well as implant survival described in the literature so far are comparable to the lateralized design. A pure comparison of how the RSA design influences outcome in patients has not yet been determined. The aim of this study was a comparison focused on patients with cuff tear arthropathy (CTA). METHODS: We analyzed registry data from 696 CTA patients prospectively collected between 2012 and 2020 in two specialized orthopedic centers up to 2 years post-RSA with the same follow-up time points (6,12 24 months). Complete teres minor tears were excluded. Three groups were defined: group 1 (inlay, 155° humeral inclination, 36 + 2 mm eccentric glenosphere (n = 50)), group 2 (inlay, 135° humeral inclination, 36 + 4 mm lateralized glenosphere (n = 141)) and group 3 (onlay, 145° humeral inclination, + 3 mm lateralized base plate, 36 + 2 mm eccentric glenosphere (n = 35)) We compared group differences in clinical outcomes (e.g., active and passive range of motion (ROM), abduction strength, Constant-Murley score (CS)), radiographic evaluations of prosthetic position, scapular anatomy and complications using mixed models adjusted for age and sex. RESULTS: The final analysis included 226 patients. The overall adjusted p-value of the CS for all time-points showed no significant difference (p = 0.466). Flexion of group 3 (mean, 155° (SD 13)) was higher than flexion of group 1 (mean, 142° (SD 18) and 2 (mean, 132° (SD 18) (p < 0.001). Values for abduction of group 3 (mean, 145° (SD 23)) were bigger than those of group 1 (mean, 130° (SD 22)) and group 2 (mean, 118° (SD 25)) (p < 0.001). Mean external rotation for group 3 (mean, 41° (SD 23)) and group 2 (mean, 38° (SD 17)) was larger than external rotation of group 1 (mean, 24° (SD 16)) (p < 0.001); a greater proportion of group 2 (78%) and 3 (69%) patients reached L3 level on internal rotation compared to group 1 (44%) (p = 0.003). Prosthesis position measurements were similar, but group 3 had significantly less scapular notching (14%) versus 24% (group 2) and 50% (group 1) (p = 0.001). CONCLUSIONS: Outcome scores of different RSA designs for CTA revealed comparable results. However, CTA patients with a lateralized and distalized RSA configuration were associated with achieving better flexion and abduction with less scapular notching. A better rotation was associated with either of the lateralized RSA designs in comparison with the classic Grammont prosthesis. LEVEL OF EVIDENCE: Therapeutic study, Level III.


Assuntos
Artroplastia do Ombro , Artropatia de Ruptura do Manguito Rotador , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Manguito Rotador/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Resultado do Tratamento , Estudos Retrospectivos
19.
JBJS Rev ; 12(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38466801

RESUMO

¼ The proximal humerus is a common location for primary bone tumors, and the goal of surgical care is to obtain a negative margin resection and subsequent reconstruction of the proximal humerus to allow for shoulder function.¼ The current evidence supports the use of reverse total shoulder arthroplasty over hemiarthroplasty when reconstructing the proximal humerus after resection of a bone sarcoma if the axillary nerve can be preserved.¼ There is a lack of high-quality data comparing allograft prosthetic composite (APC) with endoprosthetic reconstruction of the proximal humerus.¼ Reverse APC should be performed using an allograft with donor rotator cuff to allow for soft-tissue repair of the donor and host rotator cuff, leading to improvements in shoulder motion compared with an endoprosthesis.


Assuntos
Neoplasias Ósseas , Osteossarcoma , Articulação do Ombro , Humanos , Ombro/cirurgia , Ombro/patologia , Estudos Retrospectivos , Úmero/cirurgia , Osteossarcoma/cirurgia , Osteossarcoma/patologia , Neoplasias Ósseas/patologia
20.
J Orthop Surg Res ; 19(1): 180, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475917

RESUMO

BACKGROUND: Reverse Shoulder Arthroplasties (RSA) have become a primary choice for improving shoulder function and pain. However, the biomechanical failure mechanism of the humeral component is still unclear. The present study reports a novel protocol for microstructural imaging of the entire humerus implant under load before and after fracture. METHODS: A humerus specimen was obtained from a 75-year-old male donor. An expert surgeon implanted the specimen with a commonly used RSA implant (Aequalis reversed II, Stryker Orthopaedics, USA) and surgical procedure. The physiological glenohumeral contact force that maximized the distal implant migration was selected from a public repository ( orthoload.com ). Imaging and concomitant mechanical testing were performed using a large-volume micro-CT scanner (Nikon XT H 225 ST) and a custom-made compressive stage. Both when intact and once implanted, the specimen was tested under a pre-load and by imposing a constant deformation causing a physiological reaction load (650 N, 10 degrees adducted). The deformation of the implanted specimen was then increased up to fracture, which was identified by a sudden drop of the reaction force, and the specimen was then re-scanned. RESULTS: The specimen's stiffness decreased from 874 N/mm to 464 N/mm after implantation, producing movements of the bone-implant interface consistent with the implant's long-term stability reported in the literature. The micro-CT images displayed fracture of the tuberosity, caused by a combined compression and circumferential tension, induced by the distal migration of the implant. CONCLUSION: The developed protocol offers detailed information on implant mechanics under load relative to intact conditions and fracture, providing insights into the failure mechanics of RSA implants. This protocol can be used to inform future implant design and surgical technique improvements.


Assuntos
Fraturas Ósseas , Articulação do Ombro , Masculino , Humanos , Idoso , Ombro , Articulação do Ombro/cirurgia , Extremidade Superior , Úmero/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...